AS 1684 SUBFLOOR FRAMING GUIDE

Bearer & Joist Subfloor Calculator

Instantly size subfloor bearers, floor joists, concrete stump pier grids, and YellowTongue particleboard flooring for Australian residential builds and decks.

Bearer and Joist Subfloor Calculator

1. Subfloor & Framing Dimensions

m
Length of subfloor along bearer runs
m
Width across floor joist spans

2. Timber Stress Grade & Pier Grid

$
Average cost per lm of joists & bearers

Subfloor Bearer & Joist Framing Guide (AS 1684 Compliant)

In Australian residential timber framing (AS 1684.2 & AS 1684.3), subfloor structural integrity relies on correct load transfer paths: particleboard sheet flooring transfers live load to floor joists, joists transfer floor load width (FLW) to bearers, and double bearers transfer point loads to concrete stumps or masonry piers.
📐 Sizing Guide: Stuck reading AS 1684 span table columns? Read our step-by-step tutorial: How to Calculate Floor Load Width (FLW) for Bearers & Joists.

AS 1684 Subfloor Framing Principles & Load Paths

Whether you're framing a raised Queenslander subfloor, a single-storey house extension, or an elevated verandah, subfloor timber members must be sized to resist floor live loads (standard 1.5 kPa for residential rooms, 2.0 kPa for balconies and outdoor decks) without excessive deflection or bouncy spots.

Understanding Floor Load Width (FLW) & Bearer Loads

Floor Load Width (FLW) represents the tributary width of subfloor area supported by a single bearer line. For intermediate bearers supporting joists continuous over multiple spans, FLW equals half the sum of adjacent joist spans on either side.

Single Span vs Continuous Span Members

Timber joists running continuously over three or more bearers benefit from negative bending moment stiffness at intermediate supports. Continuous-span floor joists can achieve up to 15% longer allowable spans than single-span joists resting on only two bearers.

Step-by-Step Subfloor Framing Calculations

Follow these core mathematical steps used by Australian carpenters and building certifiers during material take-off generation:

Step 1: Calculate Floor Joist Runs & Lineal Metres

Determine total joist runs by dividing total subfloor length by selected joist spacing (450mm or 600mm) and adding 1 end joist:

Joist Runs = Math.ceil(Floor Length ÷ Joist Spacing) + 1
Joist Lineal Metres (lm) = Joist Runs × Floor Width × 1.10 (10% waste)

Step 2: Calculate Bearer Lines & Double Member Quantity

Standard Australian residential framing utilizes double bearer lines (two 45mm thick members fixed face-to-face with M12 bolts or framing nails):

Bearer Lines = Math.ceil(Floor Width ÷ Bearer Spacing) + 1
Bearer Lineal Metres (lm) = Bearer Lines × Floor Length × 2 × 1.10

Step 3: Calculate Concrete Stump & Pier Layout Grid

Concrete stumps or soleplate piers are placed at regular intervals along each bearer line:

Stumps Per Line = Math.ceil(Floor Length ÷ Stump Spacing) + 1
Total Stumps = Bearer Lines × Stumps Per Line

Step 4: Estimate StructaFlor Sheet Flooring Quantity

Standard 19mm StructaFlor YellowTongue sheets measure 3600mm × 900mm (3.24 m² gross area), providing 2.88 m² of effective net floor coverage after tongue-and-groove jointing:

YellowTongue Sheets = Math.ceil((Subfloor Area ÷ 2.88) × 1.10)

Timber Stress Grades & Span Table Reference (AS 1684)

Subfloor member capacity varies significantly depending on timber species, moisture content, and stress grading. Below is a quick-reference guide for standard Australian framing timber:

Timber Stress GradeCommon Member SizeMax Joist Span (450mm c/c)Max Bearer Span (Double)Primary Trade Application
MGP10 Radiata Pine140 × 45 mm2.4 m1.8 mStandard residential subfloors
MGP10 Radiata Pine190 × 45 mm3.3 m2.4 mLong-span residential joists
F7 Treated Pine (H3)150 × 50 mm2.6 m1.9 mVerandahs & outdoor decks
F17 Hardwood (KD)140 × 45 mm3.1 m2.2 mHeavy structural framing
E13 LVL Beam200 × 45 mm3.8 m2.8 mEngineered long-span subfloors

Ground Clearance & Hazard Class Rules (H3 vs H4 Treated Pine)

Timber subfloor members beneath unsealed ground must be treated against rot, fungal attack, and termites. Use H3 hazard class treated pine for above-ground framing members. Any timber stump posts set directly into concrete footings or soil must be rated H4 hazard class.

Stump & Pier Foundation Rules (AS 2870 Compliant)

Subfloor stumps and piers transfer building loads into stable foundation soil. Under AS 2870 (Residential Slabs & Footings), concrete stump pad depth depends on soil classification:

  • Class A & S Soils (Stable/Sand): Minimum 450mm embedment depth into solid ground.
  • Class M & H Soils (Reactive Clay): Minimum 600mm to 900mm embedment depth to resist seasonal ground movement.

Sheet Flooring Installation Rules (YellowTongue vs RedTongue)

StructaFlor particleboard sheet flooring is the industry standard for Australian residential subfloors:

  • 19mm YellowTongue: Formulated for floor joist spacing up to 450mm centres.
  • 22mm RedTongue: Formulated for wider floor joist spacing up to 600mm centres.
  • Joint Staggering: Lay sheets in a staggered brick pattern perpendicular to joists, ensuring short edge joints land centrally on joist faces.
  • Expansion Gaps: Leave a minimum 10mm expansion gap around the perimeter of all external brickwork or wall framing.

Worked Example: 6m × 4m Subfloor Framing Take-Off

Consider a standard 6.0m long × 4.0m wide residential house extension subfloor utilizing MGP10 Radiata Pine joists at 450mm centres and double MGP10 bearers at 2.0m spacing:

  • Floor Joists: (6.0 ÷ 0.45) + 1 = 15 runs of 4.0m length. Base = 60 lm. With 10% waste = 66.0 lineal metres of 140×45mm MGP10.
  • Double Bearers: (4.0 ÷ 2.0) + 1 = 3 lines of 6.0m length. Double members = 36 lm. With 10% waste = 39.6 lineal metres of 2/190×45mm MGP10.
  • Stump Grid: 3 bearer lines × 5 stumps per line (1.8m spacing) = 15 concrete stumps.
  • YellowTongue Sheets: (24m² ÷ 2.88) × 1.10 = 9.1610 sheets of 19mm YellowTongue.

Subfloor Cross-Ventilation & Termite Inspection Clearances

The National Construction Code (NCC Volume 2) requires subfloors to maintain unimpeded cross-ventilation to prevent dampness, timber decay, and mold:

Subfloor wall vents must provide at least 7,300 mm² of clear opening area per lineal metre of external wall. Ensure a clear inspection space of at least 150mm beneath joists for annual termite inspection under AS 3660.1.

Frequently Asked Questions

Frequently asked questions about subfloor bearer & joist framing under AS 1684